Select language:

人工對色

UV-2000F Ultraviolet Transmittance Analyzer


Features

  • One-Touch Sample Analysis; Sample Scans within Five Seconds
  • Automatic Calculations of Spectral Transmittance, UPF, Critical Wavelength and UVA:UVB Ratios
  • Performance Validation Routine
  • Automatic Calculations of UPF Parameters per AS/NZS 4399:1996, EN 13758-1:2002, AATCC 183:2010, GB/T18830:2009, Japan Garment Association Standard, and User Defined Methods

 

Labsphere's UV-2000F incorporates the latest component and software technology into an industry proven system architecture to achieve accurate UPF, critical wavelength and UVA:UVB ratio of fabric samples. Driven by rapidly evolving industry requirements to simplify research & development or quality control for fabric samples, the UV-2000F is designed to comply with recently approved testing methods such as AS/NZS 4399:1996, EN 13758-1:2002, AATCC 183:2010, GB/T18830:2009 and Japan Garment Association standard. The UV-2000F has replaced Labsphere's UV-1000F as the industry's choice for not only laboratory UPF analysis, but also production floor quality control.

The UV-2000F rapidly measures the diffuse transmittance of textile samples in the ultraviolet wavelength region from 250 - 450 nm. Labsphere's Spectralon® integrating sphere incorporates a re-optimized xenon flash lamp to provide exceptional diffuse illumination of the product sample and minimize data integration time. New high performance diode array spectrometers coupled with new, advanced fiber optics are optimized at the system level for low stray light with superior wavelength stability and flash-to-flash repeatability.

Many improvements are incorporated in the UV-2000F to realize a new industry de facto standard. System improvements include new spectrometers, xenon flash lamp, optical coupling fibers, optical head positioning mechanism, sample positioning stage and a new, robust software development platform.

The diode array spectrometers feature stable, custom concave diffractive optics for measurement integrity and repeatability, original holographic diffraction gratings (not replicated gratings) peaked for higher efficiency across the wavelength range, and longer pixel arrays for better pixel wavelength resolution. Illumination is filtered at the integrating sphere to limit total exposure at the sample and to improve stray light performance. A higher flash rate reduces exposure time, minimizing dark current and maximizing dynamic range. Use of solarization resistant fibers maintains high system throughput over time. Longer fibers filter high order modes to provide cleaner grating illumination improving stray light performance.

New capabilities of the UV-2000F include:

  • Compact bench top footprint
  • Wavelength accuracy to +/- 1 nm
  • Measurement area 0.67 cm2
  • Dynamic range extension up to 2.7 AU
  • Auto flash capability
  • USB computer interface
  • UVA:UVB ratio

* Manually operated UV-2000F sample stage assembly

A built-in report function generates essential information at the click of a button. Reports include necessary information such as date, time, operator name, sample identification and test parameters. Reports are conveniently viewed on your PC, printed, or exported as text to data processing software for further review and analysis.

UV-2000F software features different measurement methods for UPF testing of fabric samples including the AS/NZS 4399:1996, EN 13758-1:2002, AATCC 183:2010, GB/T18830:2009, Japan Garment Association standard, and user defined methods. This easy to use Windows XP® and Windows 7® compatible software facilitates capture/archival/retrieval and export of all data for various textile samples. UV-2000F application software includes an integrated Performance Validation Routine that allows for on-site validation and re-validation to ensure optimum instrument performance. A set of calibrated standards, including a wavelength standard that captures six relevant spectral bands, is included with each UV transmittance Analyzer.

 

    

Downloads

 
 

UV-2000S Ultraviolet Transmittance Analyzer


Features

  • One Touch Sample Analysis, with Results in Less Than Five Seconds
  • Manual Stage for Accurate Sample Positioning and Pre- and Post Irradiation
  • New Wavelength Standard that Captures Six Relevant Spectral Bands
  • Easy-to-Use Menu Driven Application Software
  • Simple Instrument Performance Validation Routine Ensures Accurate, Repeatable Measurements
  • Automatic Calculation of SPF, UVA to UVB ratio, critical wavelength, COLIPA - Method, Revised Boots Star Rating, ISO 24443, and FDA sunscreen testing methods

 

Labsphere's UV-2000S incorporates the latest component and software technology into an industry proven system architecture to achieve accurate in-vitro SPF/UVA-Protection Factor analysis of sun care products developed to receive the "very high" sun protection label. Driven by rapidly evolving industry requirements to simplify product labeling and new in-vitro methods to validate product UVA Protection, the UV-2000S is designed to comply with recently approved in-vitro methods, such as COLIPA UVA-PF, Boots Star Rating, 2011 FDA final rule, as well as several pending global standards/methods. The UV-2000S has replaced Labsphere's UV-1000S as the industry's choice for not only laboratory in-vitro SPF/UVA analysis, but also production floor quality control. New software has been released for the UV-2000S per the new ISO 24443 Sunscreen testing standards.

The UV-2000S rapidly measures the diffuse transmittance of sunscreen samples in the ultraviolet wavelength region from 250 - 450 nm. Labsphere's Spectralon® integrating sphere incorporates a re-optimized xenon flash lamp to provide exceptional diffuse illumination of the product sample and minimize data integration time. New high performance diode array spectrometers coupled with new, advanced fiber optics are optimized at the system level for low stray light with superior wavelength stability and flash-to-flash repeatability.

Many improvements are incorporated in the UV-2000S to realize a new industry de-facto standard for in-vitro sun care product analysis. System improvements include new spectrometers, Xenon Flash Lamp, optical coupling fibers, optical head positioning mechanism, sample positioning stage and a new, robust software development platform.

The diode array spectrometers feature stable, custom concave diffractive optics for measurement integrity and repeatability, original holographic diffraction gratings, not replicated gratings, peaked for higher efficiency across the wavelength range, and longer pixel arrays for better pixel wavelength resolution.

Illumination is filtered at the integrating sphere to limit total exposure at the sample and to improve stray light performance. A higher flash rate reduces exposure time, minimizing dark current and maximizing dynamic range.

Use of solarization resistant fibers maintains high system throughput over time. Longer fibers filter high order modes to provide cleaner grating illumination improving stray light performance.

A built-in report function generates essential information at the click of a button. Reports include necessary information such as date, time, operator name, sample identification and test parameters. Reports are conveniently viewed on your PC, printed, or exported as text to data processing software for further review and analysis.

Developed with .NET Framework®, the license controlled UV-2000S Software features different in-vitro measurement methods for UVA/UVB protection factors of sunscreen including the COLIPA, Boots Star and FDA methods. By licensing the included software, users are able to receive free upgrades on their software for one year as new methods are released to the industry. This easy-to-use Windows®  XP and 7 compatible software facilitates capture/archival/retrieval and export of all data including bare substrate data that may impact UVA-PF due to surface roughness.

UV-2000S application software includes an integrated Performance Validation Routine that allows for on-site validation and re-validation to ensure optimum instrument performance. A set of calibrated standards, including a wavelength standard that captures six relevant spectral bands, is included with each UV Transmittance Analyzer.

 

    